ESENCA
Request your audit
Back to guidesDrawing preparation

Stairs and floor slabs: information worth clarifying

Stairs and floor slabs connect the horizontal and vertical logic of a building. They can also expose gaps that remain hidden in a floor plan. Before modeling begins, give the provider enough information to understand levels, openings and intended geometry, while keeping structural design and regulatory assessment assigned to the appropriate specialists.

Explain the slab relationships

Identify the relevant floor surfaces, slab thicknesses where known and any changes in level. Mark openings, edges and areas where the reference is incomplete. Distinguish an architectural finished-floor relationship from structural information if the two are documented separately. Include sections through steps, terraces or other nonstandard transitions. Where a thickness is provisional, state that status explicitly. The modeler should not have to infer a structural solution simply because a floor outline is present in the architectural drawing.

Provide a complete stair reference

Supply the start and end levels, direction of travel, overall width and the intended landing arrangement. Include a section or detail that explains the relationship between flights and adjacent floors. Identify whether the drawing describes a measured existing stair or a proposed design. If dimensions or geometry conflict, ask the responsible architect to clarify the intended arrangement. A visually tidy stair in a model is not evidence that its dimensions, headroom or other requirements have been professionally checked.

Review connected conditions together

Check the stair, floor openings, nearby walls and relevant vertical clearances as a group. Looking at the stair alone can miss a mismatched landing or an opening that no longer aligns. Record each question against a level and location, with a screenshot or marked section where useful. When a level or slab depth changes, review the affected connections again rather than treating the change as an isolated number. Confirm which items the architectural base includes and which await engineering information.

Review the connected geometry

  • Check that the start and end levels of each stair match the floor references and that the landing arrangement is clearly documented.
  • Locate slab openings and edge conditions in both plan and section, identifying any dimensions that remain dependent on structural or architectural confirmation.
  • Record whether existing stair information was measured or inferred, and send performance or compliance questions to the professional responsible for those checks.

A short schedule of levels, a stair section and an annotated floor plan often explain more than a long message. Keep provisional dimensions in the issue register until the practice confirms them. The goal is a coherent representation of the agreed design, accompanied by clear boundaries around what has been modeled, what has been assumed and what still requires specialist review.

General guidance: each project's scope is confirmed before commissioning.

Let's talk about your capacity.

Request your capacity audit
Privacy

AEVON uses your name, email and practice details to handle your requested audit and contact you about BIM12 in response to your request. Resend forwards the notification to our inbox (info.aevon@gmail.com), where we retain your request, the notice shown, and the date and source of the request to manage your enquiry. We do not add you to advertising mailing lists. You can ask us to stop contacting you or request access, correction or deletion by emailing hola@aevon.es. Choosing the scheduling option opens Google Calendar; Google manages bookings, invitations and Google Meet under its privacy policy. Submitting the form does not confirm a meeting. This website does not use analytics or advertising.